WhatsApp
Gradient Thermal Cycler NGTC-205

Gradient Thermal Cycler NGTC-205

Gradient Thermal Cycler NGTC-205 supports a capacity of 96×0.2 ml for versatile PCR formats. It handles reaction volumes between 5 to 80 μl with precision. This unit comes with a one-click quick incubation function for rapid processing. It features a reinforced aluminum module with anodizing for efficient heat transfer and durability. Our thermal cycler includes a touchscreen display for simple and intuitive operation.


$4,875.00

Catalog

Specifications

Capacity 96×0.2ml
Tube 0.2ml tube, 8 strips
Full skirt 96 wells plate
Half skirt 96 wells plate
No skirt 96 wells plate
Reaction capacity 5 to 80µl
Temperature range 0 to 105°C
Maximum ramp rate 6°C/s
Temperature uniformity ≤±0.2°C
Temperature accuracy ≤±0.1°C
Temperature display resolution 0.1°C
Temperature control method Block/tube
Ramping rate adjustable 0.1 to 6°C/s
Hold at 4°C Forever
Gradient type Normal
Gradient speed 1 to 42°C
Gradient temperature range 30 to 105°C
Hot lid temperature range 30 to 115°C
Maximum no. of steps 30
Maximum no. of cycles 200
Maximum no. of programs 20000 + (USB Flash)
Time increment/decrement 1s to 600s
Temperature increase/decrease 0.1 to 10°C
Pause function Yes
Auto data protection Yes
Touchdown function Yes
Long PCR function Yes
Language English
Mobile phone app Yes
LCD 10.1 inch, 1280×800 pixels
Communication USB 2.0, WIFI
Power consumption 750W
Power supply 100 to 240VAC, 50/60Hz
Product dimension 385×270×255mm
Weight 10 kg

Features

  • Android operating system
  • Real-time run display
  • USB data storage
  • Long-life Peltier units
  • Front-back air channel
  • High ramp rate

Applications

  • Gradient Thermal Cycler NGTC-205 is used for amplifying DNA or RNA through precise thermal cycling in molecular biology experiments. It is widely utilized in research laboratories, clinical diagnostics, and genetic testing facilities.

Ask Expert

FAQ for Gradient Thermal Cycler NGTC-205

1: How fast is the heating and cooling rate?

The Gradient Thermal Cycler provides a maximum ramp rate of 8?°C/s, significantly reducing total run time. This is ideal for labs that require faster results without compromising quality.

2: What kind of materials is the heating block made from?

Our Gradient Thermal Cycler features a reinforced aluminum module with anodizing technology, ensuring fast thermal conductivity and high corrosion resistance. This enhances performance and extends product lifespan.

3: Does the Gradient Thermal Cycler NGTC-205 support long or complex PCR protocols?

Yes, our Gradient Thermal Cycler includes special functions for long PCR and touchdown PCR. These features help enhance amplification accuracy for complex templates and difficult targets.

4: What parts should be regularly cleaned?

The outer surface and touchscreen should be wiped with a soft, lint-free cloth to keep it clean and dust-free. Ensure that vents are not blocked to maintain proper airflow.

5: What should be done if the Gradient Thermal Cycler NGTC-205 overheats or shows an error?

Ensure that the front and rear air channels are clear and unobstructed. If the issue persists, restart the Gradient Thermal Cycler or contact technical support for assistance.

6: Can I run different sample sizes with this Gradient Thermal Cycler?

Yes, the Labnics Gradient Thermal Cycler supports various sample capacities, which is perfect for both small-scale and high-throughput experiments. You can use different formats, like 0.2 mL tubes and 96-well plates, depending on the project. This flexibility makes it very versatile in the lab.

7: Can I monitor the status of my PCR run in real-time?

Yes, our Gradient Thermal Cycler provides real-time status updates via the touchscreen interface, so you can check the progress of your run at any time. It shows detailed information such as current cycle, temperature profile, and estimated time to completion. This feature ensures that you are always aware of how your experiment is progressing.

8: Are there any routine checks I should perform on the Gradient Thermal Cycler?

It is recommended to routinely inspect the thermal cycler for any signs of wear or damage, especially the hot lid and temperature sensors. Check for consistent temperature readings and ensure all software settings are correct before starting an experiment.

9: Can the Gradient Thermal Cycler be used for high-throughput applications?

Yes, it is well-suited for high-throughput workflows due to its ability to handle multiple samples simultaneously in different formats, including 96-well and 384-well plates. This makes it perfect for labs that need to process large numbers of samples in one batch while maintaining precise temperature control.


Gradient Thermal Cycler NGTC-205

Gradient Thermal Cycler NGTC-205

Related Models Of Gradient Thermal Cycler

Labnics Gradient Thermal Cyclers offer various sample capacities to accommodate different experimental needs. They deliver consistent and accurate thermal conditions across all wells for reproducible PCR results. These units feature a user-friendly interface with intuitive programming and touchscreen navigation. They provide a large data storage capacity for saving and managing multiple protocols. Our thermal cyclers include built-in safety mechanisms to ensure secure operation.