Gradient Thermal Cycler NGTC-206

Gradient Thermal Cycler NGTC-206

Gradient Thermal Cycler NGTC-206 is designed with a 384-well capacity, ideal for large-scale PCR workflows. It enables gradient functionality with a temperature range of 1 to 42 °C for optimized conditions. This unit incorporates a front and rear air channel, allowing for efficient cooling. It supports both block and tube-based temperature control, offering adaptability. Our thermal cycler displays real-time program status and remaining time for continuous tracking.


$5,163.00

Catalog

Specifications

Capacity 384 wells
Tube 384 PCR microplates
Reaction capacity 5 to 30µl
Temperature range 0 to 105°C
Maximum ramp rate 5°C/s
Temperature uniformity ≤±0.2°C
Temperature accuracy ≤±0.1°C
Temperature display resolution 0.1°C
Temperature control method Block/tube
Ramping rate adjustable 0.1 to 5°C/s
Hold at 4°C Forever
Gradient type Normal
Gradient speed 1 to 42°C
Gradient temperature range 30 to 105°C
Hot lid temperature range 30 to 115°C
Maximum no. of steps 30
Maximum no. of cycles 200
Maximum no. of programs 20000 + (USB Flash)
Time increment/decrement 1s to 600s
Temperature increase/decrease 0.1 to 10°C
Pause function Yes
Auto data protection Yes
Touchdown function Yes
Long PCR function Yes
Language English
Mobile phone app Yes
LCD 10.1 inch, 1280×800 pixels
Communication USB 2.0, WIFI
Power consumption 600W
Power supply 100 to 240VAC, 50/60Hz
Product dimension 385×270×255mm
Weight 10 kg

Features

  • Corrosion-resistant module
  • Email notification system
  • Built-in program templates
  • Quick incubation mode
  • Long-life Peltier units
  • Touchscreen interface

Applications

  • Gradient Thermal Cycler NGTC-206 is used for amplifying DNA and RNA through precise thermal cycling, enabling various molecular biology and genetic research applications. It is commonly used in research laboratories, clinical diagnostics, and biotechnology facilities.

Ask Expert

FAQ for Gradient Thermal Cycler NGTC-206

1: Can the Gradient Thermal Cycler NGTC-206 recover after a power failure?

The Gradient Thermal Cycler has an automatic restart function that resumes the program from where it left off once power is restored. This helps protect samples and prevents experiment loss.

2: How are programs and data managed?

Our Gradient Thermal Cycler supports over 20,000 programs and allows additional storage via USB. Users can also transfer data, edit files during a run, and receive email notifications once the experiment is completed.

3: What makes the heating system reliable?

The Gradient Thermal Cycler uses long-life Peltier heating units rated for over 1,000,000 cycles. The reinforced aluminum module with anodizing enhances heat conduction and provides corrosion resistance for extended durability.

4: How often does the Gradient Thermal Cycler NGTC-206 need maintenance?

The Gradient Thermal Cycler requires minimal routine maintenance due to its robust design and long-life components. Regular cleaning of the exterior and ventilation areas is recommended to ensure optimal airflow and performance.

5: What should be done to keep the hot lid in good condition?

It’s important to gently clean the hot lid surface with a soft, lint-free cloth after use. Avoid using harsh chemicals, and always ensure the lid is not pressed down forcefully when closing.

6: Can I run different sample sizes with this Gradient Thermal Cycler?

Yes, the Labnics Gradient Thermal Cycler supports various sample capacities, which is perfect for both small-scale and high-throughput experiments. You can use different formats, like 0.2 mL tubes and 96-well plates, depending on the project. This flexibility makes it very versatile in the lab.

7: Can I monitor the status of my PCR run in real-time?

Yes, our Gradient Thermal Cycler provides real-time status updates via the touchscreen interface, so you can check the progress of your run at any time. It shows detailed information such as current cycle, temperature profile, and estimated time to completion. This feature ensures that you are always aware of how your experiment is progressing.

8: Are there any routine checks I should perform on the Gradient Thermal Cycler?

It is recommended to routinely inspect the thermal cycler for any signs of wear or damage, especially the hot lid and temperature sensors. Check for consistent temperature readings and ensure all software settings are correct before starting an experiment.

9: Can the Gradient Thermal Cycler be used for high-throughput applications?

Yes, it is well-suited for high-throughput workflows due to its ability to handle multiple samples simultaneously in different formats, including 96-well and 384-well plates. This makes it perfect for labs that need to process large numbers of samples in one batch while maintaining precise temperature control.


Gradient Thermal Cycler NGTC-206

Gradient Thermal Cycler NGTC-206

Related Models Of Gradient Thermal Cycler

Labnics Gradient Thermal Cyclers offer various sample capacities to accommodate different experimental needs. They deliver consistent and accurate thermal conditions across all wells for reproducible PCR results. These units feature a user-friendly interface with intuitive programming and touchscreen navigation. They provide a large data storage capacity for saving and managing multiple protocols. Our thermal cyclers include built-in safety mechanisms to ensure secure operation.