Nanoparticle Size and Zeta Potential Analyzer NNZPA-100 has a measurement range of 1 to 10000 nm and a zeta potential range from -500 mV to +500 mV. It supports a multilingual interface for flexible operation across different user preferences. This unit offers statistical comparisons for analyzing batch and process variations. It provides real-time test monitoring, displaying ongoing results and system status. Our analyzer uses automatic alignment to ensure accurate positioning and stable results.
$46,900.00
Specifications
Measurement Range | 1 to 10000 nm (sample-dependent) |
Zeta Potential Range | -500 mV to +500 mV |
Test Speed | < 5 minutes |
Concentration Range | 0.1 mg/mL to 100 mg/mL |
Electrophoretic Mobility | > ±20 µm.cm/V.s |
Temperature Range | 5 to 45°C |
Temperature Control Accuracy | ±0.1°C |
Highest Conductivity | 200 mS/cm (sample-dependent) |
Accuracy Error | <0.5% (D50 value), <10% (standard sample) |
Repeatability Error | <0.5% (D50 value), <10% (standard sample) |
Laser Source | Semiconductor laser λ=635 nm P = 1 to 40 mW (adjustable) |
Detector | Photomultiplier tube |
Scattering Angles | 90°, 18° |
Sample Cell Volume | 10 mm × 10 mm × 40 mm (1 to 4 mL) 10 mm × 10 mm × 60 mm (1 mL) |
Digital Correlator Model | HA1024 |
Auto-Correlation Channels | 892 |
Baseline Channels | 4 |
Physical Channels | 5000 |
Unit Delay Time | 1 μs to 10 ms (adjustable) |
Dimension | 560 × 450 × 300 mm |
Packing Dimension | 860 × 730 × 500 mm |
Net Weight | 20 kg |
Gross Weight | 55 kg |
Features
Applications
Standard Accessories
Analysis Software × 1 set
Standard Material × 1 bottle
Power cable × 1 pc
Communication line × 1 pc
Syringes (1 ml) × 5 pcs
Syringes(10 ml) × 2 pcs
Sample cuvette × 50 pcs
Lens cleaning paper × 5 pcs
Tool bag × 1 pc
Zeta potential sample cell × 2 pcs
Ask Expert
FAQ for Nanoparticle Size and Zeta Potential Analyzer NNZPA-100
1: How does the Nanoparticle Size and Zeta Potential Analyzer NNZPA-100 ensure accurate zeta potential readings?
The Nanoparticle Size and Zeta Potential Analyzer NNZPA-100 features a zeta potential range of -500 mV to +500 mV, allowing it to reliably measure surface charge characteristics and assess colloidal stability in a wide range of samples.
2: Why is automatic alignment important in the Nanoparticle Size and Zeta Potential Analyzer NNZPA-100?
Our Nanoparticle Size and Zeta Potential Analyzer NNZPA-100 uses automatic alignment to ensure correct optical positioning, which enhances result consistency and reduces user-dependent errors during measurement.
3: Does the Nanoparticle Size and Zeta Potential Analyzer NNZPA-100 allow custom refractive index input?
The Nanoparticle Size and Zeta Potential Analyzer NNZPA-100 allows users to define a custom refractive index, which improves accuracy when analyzing samples with unique optical properties.
4: What should I do if the Nanoparticle Size and Zeta Potential Analyzer NNZPA-100 shows inconsistent readings?
If the Nanoparticle Size and Zeta Potential Analyzer NNZPA-100 provides inconsistent results, check for proper sample dispersion, verify alignment, ensure correct cuvette placement, and confirm that suitable measurement settings are used.
5: Does the Nanoparticle Size and Zeta Potential Analyzer NNZPA-100 support real-time monitoring?
Yes, the Nanoparticle Size and Zeta Potential Analyzer NNZPA-100 supports real-time test monitoring, allowing users to view ongoing results and system status throughout the analysis process.
6: How does the Nanoparticle Size and Zeta Potential Analyzer ensure high accuracy in measurements?
The Nanoparticle Size and Zeta Potential Analyzer is equipped with a high-speed HA1024 digital correlator that processes light scattering data in real time. This allows it to accurately reflect particle movement and deliver precise results for both size and zeta potential analyses.
7: How does the Nanoparticle Size and Zeta Potential Analyzer maintain temperature stability during testing?
Our Nanoparticle Size and Zeta Potential Analyzer features semiconductor-based temperature control technology, maintaining an accuracy of ±0.1 °C. This ensures consistent test conditions by minimizing variations in liquid viscosity and particle motion due to temperature fluctuations.
8: Is the Nanoparticle Size and Zeta Potential Analyzer suitable for analyzing materials with different refractive indices?
Yes, it supports customizable refractive index models, which enhance measurement accuracy across a wide variety of substances. This makes the Nanoparticle Size and Zeta Potential Analyzer effective for testing emulsions, dispersions, polymers, and biological suspensions.
9: What file formats can be used to export data from the Nanoparticle Size and Zeta Potential Analyzer?
The Nanoparticle Size and Zeta Potential Analyzer supports multiple output formats, including BMP, TXT, Word, and Excel files. This flexibility allows the Nanoparticle Size and Zeta Potential Analyzer to seamlessly integrate into digital workflows for reporting, archiving, or further analysis.
Labnics Nanoparticle Size and Zeta Potential Analyzers incorporate unconstrained free fitting technology for more accurate and flexible data analysis. They support multiple export formats for easy data sharing and analysis. These units feature a compact design to save space and enhance portability. They provide a multilingual interface to support users across different language preferences. Our analyzer offers real-time test monitoring for continuous observation and precise control of measurements.